Owens Corning R13 Insulation 16 x 96 Faced Fiberglass Batt
OC Faced Formaldehyde-free ™ fiberglass insulation is excellent for efficient thermal as well as noise management. Owens Corning Faced insulation is conveniently available in pre-cut batts to fit typical wall surface and ceiling locations. Boost the total efficiency of your house with fiberglass wall surface bay insulation. It’s thermal performance aids to maintain temperature levels down, lessening power loss as well as power expenses while furthermore decreasing space to room audio transmission.
- Easy to install: Precut batts friction fit in common spaces
- Excellent thermal control
- Soundproof: Effective acoustical control
- Effective Moisture Control: Vapor barrier keeps moisture out
- Fiberglass Insulation Batt: 16 in. x 96 in.x 3.5 in. thick
- Long Term Performance: will not settle nor slump
- Bags per Master Pack: 5
- Pieces per Bag : 13
- Square feet per Bag: 138.67
- Best For: 2×4 Interior walls, 2×4 Exterior Walls, Sheds, Basement Walls
- Certified GREENGUARD GOLD CertifiedSM and validated to be formaldehyde free2, to contain at least 55% recycled content, and Contributes to LEED® project certification
- Product Data Sheet -Click here
About R 13 Insulation
Homeowners look for EcoTouch ® PINK ® FIBERGLAS ™ Insulation with PureFiber ® Technology fast and also easy to install. Additionally, EcoTouch ® insulation:
Delivers comfort- really helps homes remain cooler in the summer and also warmer in the winter season Will reduce monthly home heating and cooling down costs1 for the life of the house Offers Owens Corning’s phenomenal thermal as well as acoustical efficiency
Sustainability Benefits:
Qualified to include a minimum of 58% total recycled content ** Formaldehyde free
Insulating Outside Walls with R 13 Fiberglass is best for Thermal Insulation
Shielding exterior wall surfaces properly is important for protecting your house from the elements. Insulate outside wall surface spaces with fiberglass insulation. This helps give reliable water management and air sealing off to keep your clients’ residences comfortable.
Insulating Basement Walls with R 13 Insulation
A dry as well as comfy cellar indicates a completely dry as well as comfy living space above. In a warm basement, insulate cellar wall surfaces with existing (or included) 2×4 wall studs with Kraft paper-faced or unfaced outside wall surface insulation. Prior to insulating, all foundation walls need to be looked for water seapage and restorative action taken. Install an interior finish material, such as drywall, as quickly as the insulation is in place. It is not needed to insulate the ceiling in a warmed basement, yet it will certainly assist regulate noise between floorings.
Insulating indoor Wall Surfaces with R 13 for Sound Proofing
Aiming to deaden sound in specific areas in your home? Put in R 13 on 2×4 wall bays to help deaden sounds in between rooms. This application is fantastic around washrooms where you do not intend to hear intruding sounds. Also possibly quiet down the Master bedroom so you can appreciate the privacy of your suite. R 13 insulation is the perfect low cost way to help improve the performance of your house as well as offer sound reducing between living areas by installing with 2×4 stud wall surfaces. No vapor barrier is required so unfaced should finish the job.

About Owens Corning Insulation
Owens Corning ® EcoTouch ® PINK ® Fiberglas ™ Insulation with PureFiber ® Tech is a preformed, adaptable blanket insulation. It is made in R-values from 11 to 49, with densities varying from 31/2 inches to 14 inches. It is offered unfaced, or faced with either a kraft or foil vapor retarder.
Owens Corning is produced with less dust than other fiberglass product lines, EcoTouch ® PINK ® Fiberglas ™ insulation has superb firmness and also recovery attributes. They make use of compression product packaging which speeds work site handling as well as installment.
Applications for R 13
- Wood-framed wall surface, flooring and roof/ceiling cavity wall surface installations
- Metal-framed wall surface as well as sub-floor bay installments
- Furring strips set up on the interior side of basement wall surfaces
- Indoor surfaces of basement and also unvented crawl space foundation surfaces
Installment of R 13 Insulation
See Owens Corning magazine “Setup Guide for Light Density
Insulation” (Club. No. 10017858) to find out more.
Environmentally Friendly and also Sustainability
Owens Corning is a worldwide leader in construction product
systems, insulation and also composite remedies, supplying a broad series of premium services and products. Owens Corning is dedicated to driving sustainability by providing services,
transforming markets as well as enhancing lives. More details can be located at www.owenscorning.com.
Owens Corning is a global business that establishes as well as produces insulation, roof, as well as fiberglass compounds. It was developed in 1935 as a collaboration in between 2 significant American glassworks, Corning Glass Works as well as Owens-Illinois. The company employs around 19,000 people around the world.

Insulating Walls with R13 Fiberglass
When you are insulating (2×4 and also (2×6) mounted outside wall cavities and also want to install fiberglass insulation, what density is ideal? The inquiry ends up being all more critical because of the permanent nature of wall assembly and wall insulation: Once the insulation is installed the wall and also nailed up with drywall, it is not easy to swap out.
When you install inadequate insulation, you will have a chillier house. However adding too much insulation- packing in greater than is needed- can additionally result in a cooler house than is necessary. Tiny air pockets developed within the insulation are what help maintain a house toasty and also warm, not the tiny strands of fiberglass or paper kraft facing. Striking an excellent equilibrium in between insufficient insulation and excessive insulation will keep you and also your family members warm throughout the winter season.
Fundamentals of Kraft Faced/Unfaced Fiberglass Insulation, From R-13 to R Nineteen
R-value is a basic system of measurement for identifying, among lots of points, exactly how efficient your insulation will certainly be. The R describes outright thermal resistance. Greater R-value numbers indicate that the insulating material resists the cold or heat from the outdoors better. Thickness, width, and composition of materials are some elements that contribute to R-value.
R13 Insulation for 2×4 Walls
The majority of wall assemblies, particularly those in older homes, are built with two-by-four (2×4) studs. Because modern-day two-by-fours are not 4 inches, the true depth of the wall bay is 3 1/2 inches.
In a lot of wall cavity applications, you will utilize R-13 or R-15 kraft-faced fiberglass precut batts for these 2 by 4 stud bays. While ranked in a different way, these two kinds of insulation are close enough in thickness that they can both match modern two-by-four wall systems. With R15 being a high density product, it is far superior for soundproofing. However it costs about 70 percent more than R-13.
Older residences, specifically those pre-dating the 1950s, may employ two-by-fours that truly are 2 inches by 4 inches. In this situation, you can still install R-13 or R-15 fiberglass insulation. There is no 4-inch thick faced fiberglass insulation in batts or rolls on the common market.
Owens Corning insulation is sold in huge box stores as well as additionally can be bought via distributors like Pacific Insulation. Pacific Insulation offers an unique opportunity to get the exact same products at store at wholesale pricing. Homeowner and also service providers have the chance to buy little or huge quantities direct from the distributor. By buying straight from the distributor we are able to use reduced prices. Customers can get from among our 70 distribution points or we can deliver straight to your project.
Rates can vary by place in the US. Costs can vary by area in the United States. Call Us Now (424)343-6530 or Message Us Now for bulk pricing.
U.S. Department of Energy Recommended Total R-Values
The following 2008 Department of Energy zone recommendations are based on comparing estimated future energy savings to the current cost of installing insulation. The DOE gives a range for many locations for the following reasons:
- Energy costs vary greatly over each zone
- Installed insulation costs vary greatly over each zone
- Heating and cooling equipment efficiency varies from house to house
- Best estimate of future energy costs may not be exact. 1Reference : Department of Energy Insulation Fact Sheet
(DOE/CE-0180 2008 update) DOE/CE-0180 2008, Insulation Fact Sheet.

Costs can vary by area in the United States. Call Us Now (424)343-6530 or Message Us Now for bulk pricing.
Reviews
There are no reviews yet.